Skip to content
Close-up of a technician's hands on a red refrigerant manifold gauge beside an outdoor AC unit

Licensing

HVAC License in Florida (2026): Air-Conditioning and Mechanical Contractors

By· Founder, Made For BuildersReviewed

Summary

Florida HVAC licenses at a glance

Florida has three license categories for HVAC businesses that new applicants can pursue: Class A air-conditioning, Class B air-conditioning and mechanical contractor. Class C still exists, but only for people licensed on October 1, 1988. All of them sit in Division II of the CILB, within the Department of Business and Professional Regulation (DBPR).

HVAC contractor categories in Florida (Florida Statutes ch. 489, part I, checked 2026-11-10)
ItemClass A air-conditioningClass B air-conditioningMechanical contractorClass C air-conditioning
Scope (s. 489.105)Unlimited: central air-conditioning, refrigeration, heating and ventilating systems, with duct work for a complete systemSame kinds of systems, limited to 25 tons of cooling and 500,000 Btu of heating in any one systemUnlimited, as Class A, plus lift station equipment, gas lines within buildings and other process pipingServicing only
Open to new applicantsYesYesYesNo: only those licensed as of October 1, 1988
Experience (s. 489.111)For example, 4 years, with at least 1 as a foreman; or 1 year as a certified Class BFor example, 4 years, with at least 1 as a foremanFor example, 4 years, with at least 1 as a foremanCan move to Class B after 3 years or Class A after 4 years, with the exam
ExamState exam approved by the board (s. 489.113)State exam approved by the boardState exam approved by the boardClass B or Class A exam to upgrade
Statutory fee caps (s. 489.109)Application up to $150 ($350 with the exam); certification and renewal up to $250Same capsSame capsSame caps
Fees shown are statutory ceilings. Actual fees and insurance minimums come from Board rule (Chapter 61G4, Florida Administrative Code), which we could not read on DBPR's site; check the application before paying.

Business vs personal

Do you need a license to run an HVAC business in Florida?

Yes. Florida law says a person must be certified or registered in order to engage in the business of contracting in the state, and other contractors must subcontract air-conditioning and mechanical work unless they hold that trade's certificate or registration. Technicians who handle refrigerant also need the federal EPA Section 608 certification.

Under s. 489.105, the work of Class A and Class B air-conditioning contractors includes central air-conditioning, refrigeration, heating and ventilating systems, with duct work for a complete system, and any duct cleaning and equipment sanitizing that requires at least a partial disassembling of the system. The scope also covers repairing or replacing power wiring, disconnects, breakers or fuses for dedicated HVAC circuits with proper use of a circuit breaker lock; low voltage heating, ventilating and air-conditioning control wiring; and installing a condensate drain from an air-conditioning unit to an existing safe waste. It excludes potable water lines, sanitary sewer lines, swimming pool piping and filters, and electrical power wiring. Gas fuel lines inside buildings are also excluded, except for disconnecting or reconnecting changeouts of gas appliances.

  • Mechanical contractor: same unlimited systems as Class A, plus lift station equipment and piping; gasoline tanks and pump installations, standpipes, air piping, vacuum line piping, oxygen lines and nitrous oxide piping; and liquefied petroleum gas and natural gas fuel lines within buildings.
  • Testing and evaluating systems: allowed under these licenses, though the statute creates no mandatory license for those services alone.
  • Small plug-in units: the license law does not apply to anyone who sells, services or installs heating or air-conditioning units of no more than 3 tons or 36,000 Btu that have no ducts and a factory-installed cord and plug (s. 489.103).
  • Minor work: work of a casual, minor or inconsequential nature under $2,500 is exempt, but not for anyone who advertises as a contractor (s. 489.103).
  • Journeyman cards are local: counties and municipalities may issue journeyman licenses in the mechanical or HVAC trades to people who scored at least 75 percent on a proctored journeyman exam and completed a registered apprenticeship or at least 12,000 hours of on-the-job training. A journeyman card does not license the business (s. 489.1455).
  • Refrigerant: EPA rules require certification for technicians who could release refrigerants, and only Section 608 certified technicians can buy refrigerant for stationary systems. See EPA 608 certification for HVAC.

Working without a license

Under s. 489.128, contracts entered into by an unlicensed contractor are unenforceable in law or in equity by that contractor, and no lien or bond claim exists in the unlicensed contractor's favor.

Steps

Steps to get a certified HVAC contractor license in Florida

Meet an experience route in s. 489.111, pass the state exam for your category, then file the application with a credit report, an insurance affidavit and fingerprints. A company applies through its qualifying agent. The certificate is not transferable and is valid anywhere in the state.

  1. 1. Experience and exam

    You must be 18 and of good moral character. The main routes are: at least 4 years of active experience as an apprentice-trained worker or foreman, with at least 1 year as a foreman; a 4-year degree in engineering, architecture or building construction plus 1 year of proven experience in the category; or a combination such as 1 year as a foreman plus 3 years of college credits. The statute counts 2,000 person-hours as a year. You then pass the examination approved by the board for your category, and DBPR issues the certificate to each person the Board finds qualified.

  2. 2. Financial responsibility

    With the initial application you file a credit report from a nationally recognized credit agency. The Board may set net worth, cash and bonding guidelines of no more than $10,000 for Division II certificateholders, which include air-conditioning and mechanical contractors. Half of those requirements may be met with a 14-hour financial responsibility course approved by the Board (s. 489.115).

  3. 3. Insurance and workers' compensation

    You sign an affidavit that you have workers' compensation, public liability and property damage insurance, in amounts set by Board rule. If you plan to claim a workers' compensation exemption, you attest that you will obtain it within 30 days after the license is issued. In construction, Florida's workers' compensation law covers private employment with one or more employees. No more than three corporate officers may elect to be exempt, and each must own at least 10 percent of the stock (s. 440.02). Evidence of coverage is a condition of issuance and renewal (s. 489.114).

  4. 4. Background check and business registration

    Initial applicants submit fingerprints and a statewide criminal history records check through the Florida Department of Law Enforcement. A sole proprietor's license is issued only to that individual; a company applies through its qualifying agent (s. 489.119).

  • Registered instead of certified: a registration needs no state exam. You file evidence of the local exam and license, and you may contract only in the counties or municipalities where you met local requirements (s. 489.117).
  • Qualifying agent leaves: the company has 60 days to employ another. Primary qualifying agents share responsibility for supervising the business (s. 489.1195).
  • License number: it goes on each building permit application and in each offer of services, bid, contract or advertisement, regardless of medium, and on vehicles that carry the business name (s. 489.119).

Class A, B or mechanical

Choosing between Class A, Class B and mechanical

The difference is system size and piping. Class B stops at 25 tons of cooling and 500,000 Btu of heating in any one system. Class A has no size limit. Mechanical adds process piping and gas lines within buildings. An active certified Class B contractor can move to Class A after 1 year and the Class A exam.

  • Class B to Class A: an active certified Class B contractor is eligible for Class A after passing the Class A exam with a minimum of 1 year of proven experience in the classification (s. 489.111).
  • Class C to Class B or A: an active certified Class C contractor can move to Class B with 3 years of proven experience, or to Class A with 4 years, after passing the relevant exam.

Costs

Florida HVAC license fees and renewal

Statute caps the fees; Board rule sets the amounts. A certificate application costs at most $150 ($350 with the exam), and certification or renewal at most $250. Renewal comes every 2 years.

Statutory fee caps, s. 489.109, Florida Statutes (checked 2026-11-10)
ItemCap or amount
Initial application, certificateUp to $150; up to $350 combined if the exam cost is included
Initial certification and biennial renewalUp to $250
Initial application, registrationUp to $100
Initial registration and biennial renewalUp to $200
Qualifying a business organization$50 application and $50 renewal
Insurance, credit report, fingerprints, exam prepSet by your providers; we do not estimate them
  • Continuing education: at least 14 classroom hours each biennium, of at least 50 minutes each. Part must cover workers' compensation, business practices and workplace safety, and 1 hour must deal with laws and rules (s. 489.115).

Endorsement

Moving to Florida with an out-of-state HVAC license

Florida offers certification by endorsement. Section 489.115 lists routes including a substantially equivalent exam, a license from a state with a reciprocal agreement with the Board, or a valid license from another state held for at least 10 years. You still file an application with the CILB.

Under the 10-year route, you apply for the same or similar license, either while the out-of-state license is active or within 2 years after it was last active. The statute does not list which states have reciprocal agreements; ask the CILB before you rely on one. Journeyman cards work differently: counties and municipalities must recognize a journeyman license in the mechanical or HVAC trades issued by another Florida county or municipality. Your EPA Section 608 certification is federal and does not expire, so it moves with you. The reverse is not true: a Florida certificate gives you no right to contract in Texas, Georgia, Arizona or North Carolina. See HVAC license by state, business vs personal HVAC licenses, and the Florida guides for plumbing and electrical contractors.

Single-story stucco and stone home with a palm and a three-car garage in Odessa, Florida

First jobs

After the license: getting your first HVAC jobs in Florida

Florida summers fill HVAC schedules, but only for companies customers can find. Start with what you own: a Google Business Profile, a basic site and early reviews. Buy leads only after your margins are known, and judge each source by cost per installed or repaired system.

HVAC partners wanted in Florida

Florida is a launch market for the Partner Program. Made For Builders operates an HVAC brand for your service area and routes its calls to your team. We charge 20% of the labor on service and repair jobs, and 15% of the net on installations and replacements; with no setup fee or monthly fee (how commission works). Each job runs on your Florida certificate and insurance, since we are not an HVAC contractor.

FAQ

Florida HVAC license: questions

How long does it take to get an HVAC license in Florida?

Mostly as long as the experience takes: usually 4 years, at least 1 of them as a foreman, or 1 year after a 4-year engineering, architecture or building construction degree (s. 489.111). The exam and application come after that.

Can you work HVAC with no license in Florida?

Not as a contractor. A person must be certified or registered to engage in the business of contracting. The statute exempts selling, servicing or installing ductless plug-in units of no more than 3 tons or 36,000 Btu, and minor work under $2,500 if you do not advertise as a contractor. Handling refrigerant also requires EPA Section 608 certification.

What is HVAC salary in Florida?

We have not verified a Florida figure. Nationally, the BLS reports a median annual wage of $61,010 for HVAC mechanics and installers in May 2025, and the highest 10 percent earned more than $95,210. Those are employee wages, not what an HVAC business earns.

What license does an HVAC company need in Florida?

A state certificate or registration as a Class A or Class B air-conditioning contractor or a mechanical contractor, held by the company's qualifying agent. A sole proprietor's license is issued only to that individual. Technicians who handle refrigerant also need EPA Section 608 certification.

What is the difference between Class A and Class B in Florida?

Size. A Class A air-conditioning contractor's services are unlimited. A Class B contractor is limited to 25 tons of cooling and 500,000 Btu of heating in any one system. Both take the state exam for their class, and a certified Class B contractor can move to Class A after 1 year.

Sources

Sources

Sources

  1. Florida Statutes s. 489.103 (exemptions) (opens in a new tab)Accessed
  2. Florida Statutes s. 489.105 (definitions, air-conditioning and mechanical contractors) (opens in a new tab)Accessed
  3. Florida Statutes s. 489.107 (Construction Industry Licensing Board) (opens in a new tab)Accessed
  4. Florida Statutes s. 489.109 (fees) (opens in a new tab)Accessed
  5. Florida Statutes s. 489.111 (licensure by examination) (opens in a new tab)Accessed
  6. Florida Statutes s. 489.113 (qualifications for practice) (opens in a new tab)Accessed
  7. Florida Statutes s. 489.114 (workers' compensation coverage) (opens in a new tab)Accessed
  8. Florida Statutes s. 489.115 (certification, endorsement, renewal, continuing education) (opens in a new tab)Accessed
  9. Florida Statutes s. 489.117 (registration) (opens in a new tab)Accessed
  10. Florida Statutes s. 489.119 (business organizations; qualifying agents) (opens in a new tab)Accessed
  11. Florida Statutes s. 489.1195 (responsibilities of qualifying agents) (opens in a new tab)Accessed
  12. Florida Statutes s. 489.128 (contracts by unlicensed contractors) (opens in a new tab)Accessed
  13. Florida Statutes s. 489.1455 (journeyman; reciprocity) (opens in a new tab)Accessed
  14. Florida Statutes s. 440.02 (workers' compensation definitions) (opens in a new tab)Accessed
  15. US EPA: Section 608 Technician Certification Requirements (opens in a new tab)Accessed
  16. US EPA: Refrigerant Sales Restriction (opens in a new tab)Accessed
  17. BLS Occupational Outlook Handbook: Heating, Air Conditioning, and Refrigeration Mechanics and Installers (opens in a new tab)Accessed

Next steps

Where to go from here

  • Your trade

    How the Partner Program works for your trade: the jobs, the licensing check and how commission is paid.

    See your trade
  • Run your numbers

    A free calculator to check the margin on a job before you price it.

    Open the calculator
  • Working in this state

    Who regulates your trade here, the official sources and where we are recruiting partners.

    See the state page
  • Licensing

    What you need to run a trade business legally, from official sources.

    All licensing guides
  • How the Partner Program works

    We build and run a local brand for your trade in your area. The calls ring on your phone and you pay commission only on jobs you close.

    See the Partner Program
  • Apply to the Partner Program

    Calls from your own area under a local brand. Commission only on closed jobs.

    Apply

Last reviewed: